Alabama Professional Home Inspection Services (APHIS)
Protecting Your Most Valuable Investment
 
Home
About Us
Fees
Inspection Agreement
Schedule an Inspection
Sample Report
Testimonials
Links
News Feeds
HomeGauge
User Name
Password

Lost Password?








Click

Sample Home Inspection Report

Inspection Report

Prepared For:
Albert Smith
Jane Smith

Property Address:
123 Main St.
Your Town, AL 356XX

APHIS

Don Combest -AL License: HI-0779
P.O. Box 1228
Athens, AL 35612
256-216-0021



Date: 1/19/2006 Time: 7:10 AM Report ID: 06-xxx
Property:
123 Main St.
Your Town, AL 356XX
Customer:
Albert Smith
Jane Smith
Real Estate Professional:

Client Is Present:
Yes

Age Of Home:
Under 10 Years

Weather:
Clear

Temperature:
Below 50

Rain in last 3 days:
Yes




ROOF

 NINPN/AYNSatPRMI
1.0 ARE THERE ANY NOTICEABLE SWAYS OR SAGS IN THE ROOF SHEATHING    X   
1.1 ARE THERE MULTIPLE LAYERS OF ROOF COVERINGS    X   
1.2 DOES THE ROOF COVERING APPEAR TO BE IN SERVICEABLE CONDITION   X    
1.3 IS DRIP EDGE INSTALLED ALONG ROOF PERIMETER   X    
1.4 WHAT IS THE CONDITION OF FLASHING     X  
1.5 DOES ROOF VENTILATION APPEAR ADEQUATE   X    
1.6 WHAT IS THE CONDITION OF SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS     X  
1.7 WHAT IS THE CONDITION OF RAIN GUTTERS     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
VIEWED ROOF FROM:
LADDER AT EAVES
 
ROOF-TYPE:
GABLE
 
ROOF COVERING:
3-TAB FIBERGLASS
ARCHITECTURAL
 
VENTILATION:
GABLE VENTS
SOFFIT VENTS
THERMOSTATICALLY CONTROLLED
 
CHIMNEY:
N/A
 
SKY LIGHT (S):
NONE
 

EXTERIOR WALLS & EAVES

 NINPN/AYNSatPRMI
2.0 WHAT IS THE CONDITION OF SOFFIT, FASCIA, TRIM AND EAVES     X  
2.1 WHAT IS THE CONDITION OF EXTERIOR WALL COVERINGS, FLASHING       X
2.2 WHAT IS THE CONDITION OF FOUNDATION WALLS AND MORTAR JOINTS (exterior)     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
SIDING STYLE:
BRICK
SHIPLAP
 
SIDING MATERIAL:
BRICK VENEER
COMPOSITE BOARD
 
SOFFIT MATERIAL:
VINYL
 
FASCIA MATERIAL:
PAINTED WOOD
 
Comments:
2.1 Composite board siding at rear of home at upper deck deteriorated, and needs replacing.

2.1 Picture 1

EXT. WINDOWS & DOORS

 NINPN/AYNSatPRMI
3.0 WHAT IS THE OUTSIDE CONDITION OF WINDOWS AND/OR SKYLIGHTS      X 
3.1 WHAT IS THE CONDITION OF SLIDING GLASS AND/OR PATIO DOORS     X  
3.2 WHAT IS THE CONDITION OF EXTERIOR ENTRY DOORS       X
3.3 WHAT IS THE CONDITION OF STORM AND/OR SCREEN DOORS     X  
3.4 IS DOOR CHIME OPERATIONAL   X    
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
ENTRY DOORS:
FIBERGLASS
STEEL
 
INTERIOR DOORS:
HOLLOW CORE
MASONITE
 
WINDOWS:
WOOD
 
WINDOW TYPES:
DOUBLE-HUNG
 
WINDOW MANUFACTURER:
UNKNOWN
 
Comments:
3.0 Sillplate and Brickmold deteriorated and needs replacing to prevent possible water intrusion at front of home and rear of home.

3.0 Picture 1

3.0 Picture 2

3.0 Picture 3

3.0 Picture 4

3.0 Picture 5

3.0 Picture 6

3.0 Picture 7

3.0 Picture 8

3.0 Picture 9

3.0 Picture 10
3.2 Rear entry door at Sun room has deteriorated at brickmold or trim (exterior). Needs repair or replace, prep and paint.

Rear entry door at Family room rubs at sill and has deteriorated at brickmold or trim (exterior). Needs repair or replace, prep and paint.

Main entry door at Foyer does not fit opening properly (out of square) and needs strike adjustment for deadbolt and door knob to latch properly.

Rear entry door at Family room has damaged or aged weather stripping.



3.2 Picture 1

3.2 Picture 2

3.2 Picture 3

3.2 Picture 4

3.2 Picture 5

3.2 Picture 6

3.2 Picture 7

DECKS & PORCHES

 NINPN/AYNSatPRMI
4.0 WHAT IS THE CONDITION OF PORCH, PATIO OR DECK     X  
4.1 WHAT IS THE CONDITION OF DECKS, STAIRS AND HANDRAILS OR BALCONIES       X
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
APPURTENANCE:
COVERED PORCH
DECK WITH STEPS
 
Comments:
4.1 Guardrails and pickets on steps to basement at left side of home (facing front) loose and needs tighten or repair.

4.1 Picture 1

LANDSCAPING AND DRAINAGE

 NINPN/AYNSatPRMI
5.0 DOES LANDSCAPE FAVOR PROPER DRAINAGE       X
5.1 WHAT IS THE CONDITION OF WALKWAYS AND DRIVEWAY       X
5.2 WHAT IS THE CONDITION OF RETAINING WALL(S), (AS IT PERTAINS TO PROPER DRAINAGE)       X
5.3 DOES LANDSCAPING FAVOR PROPER AIR FLOW/VENTILATION AROUND EXTERIOR WALLS   X    
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
DRIVEWAY:
CONCRETE
 
SIDEWALKS:
BRICK
CONCRETE
 
Comments:
5.0 Dirt bank at left side (facing front) and right side (facing front) is eroding. Silt travel is occurring and has pushed against fence and gates causing damage to gates.  Recommend some form of ground cover or landscaping and repairing gates..

5.0 Picture 1

5.0 Picture 2

5.0 Picture 3

5.0 Picture 4
5.1 Concrete drive at front of home shows signs of erosion and problem needs to be addressed.

5.1 Picture 1
5.2 Retaining wall has shifted somewhat, but it appears as old settlement. Wall appears stable at present.

5.2 Picture 1

GARAGE

 NINPN/AYNSatPRMI
6.0 WHAT IS THE CONDITION OF GARAGE DOOR OPERATORS     X  
6.1 DO THE GARAGE DOOR(S)"REVERSE" WITH SAFETY BEAM   X    
6.2 DO THE GARAGE DOOR(S)"REVERSE" WITH RESISTANCE   X    
6.3 WHAT IS THE CONDITION OF GARAGE DOOR(S)     X  
6.4 IS THERE ANY EXPOSED WIRING ON CEILING LOWER THAN 7 FEET FROM GARAGE FLOOR    X   
6.5 ARE OUTLETS GFCI PROTECTED       X
6.6 WHAT IS THE CONDITION OF WALLS AND CEILING     X  
6.7 WHAT IS THE CONDITION OF GARAGE FLOOR     X  
6.8 WHAT IS THE CONDITION OF WINDOWS  X     
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
STRUCTURE:
ATTACHED GARAGE
 
OPENER MANUFACTURER:
1/2 HORSEPOWER
LIFT-MASTER
 
GARAGE DOOR MATERIAL:
INSULATED
METAL
 
TYPE:
ONE AUTOMATIC
 
Comments:
6.5 GFCI outlet did not trip when tested. Recommend repair by a licensed electrical contractor..
6.8 No windows in garage.

KITCHEN

 NINPN/AYNSatPRMI
7.0 WHAT IS THE CONDITION OF THE CEILING     X  
7.1 WHAT IS THE CONDITION OF THE WALLS     X  
7.2 WHAT IS THE CONDITION OF THE FLOOR     X  
7.3 WHAT IS THE CONDITION OF THE WINDOWS     X  
7.4 WHAT IS THE CONDITION OF THE DOORS     X  
7.5 WHAT IS THE CONDITION OF THE OUTLETS AND WALL SWITCHES     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
CEILING MATERIAL:
SHEETROCK
 
WALL MATERIAL:
SHEETROCK
 
FLOOR COVERING(S):
HARDWOOD T&G
 

KITCHEN COMPONENTS

 NINPN/AYNSatPRMI
8.0 WHAT IS THE OVER-ALL CONDITION OF KITCHEN FIXTURES AND APPLIANCES     X  
8.1 WHAT IS THE CONDITION OF THE CABINETS     X  
8.2 WHAT IS THE CONDITION OF THE COUNTER TOPS.     X  
8.3 WHAT IS THE CONDITION OF PLUMBING UNDER SINK   X    
8.4 ARE CUT-OFF VALVES UNDER SINK   X    
8.5 WHAT IS THE CONDITION OF FAUCET AND SPRAY NOZZLE     X  
8.6 IS DISPOSER OPERATIONAL   X    
8.7 IS THE COOKTOP/OVEN OR RANGE OPERATIONAL   X    
8.8 IS THE RANGE VENTILATION OPERATIONAL   X    
8.9 IS THE OUTLET FOR REFRIGERATOR 3 PRONG GROUNDED OR ACCESSIBLE   X    
8.10 ARE THE OUTLETS WITHIN SIX FEET OF THE SINK GFCI   X    
8.11 IS DISHWASHER OPERATIONAL   X    
8.12 WHAT IS THE CONDITION OF THE WASHER/DRYER CONNECTIONS     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
CABINETRY:
WOOD
 
COUNTERTOP:
LAMINATE
 
DISHWASHER:
KITCHEN AIDE
 
DISPOSER:
KITCHEN AIDE
 
RANGE/OVEN:
KITCHEN AIDE
 
EXHAUST/RANGE:
KITCHEN AIDE
 
BUILT-IN MICROWAVE:
KITCHEN AIDE
 
REFRIGERATOR:
NONE
 
TRASH COMPACTOR:
NONE
 
WASHER DRAIN SIZE:
2" DIAMETER
 
DRYER VENT:
METAL
 
DRYER POWER SOURCE:
22O ELECTRIC
 

Formal Dining Room

 NINPN/AYNSatPRMI
9.0.A WHAT IS THE CONDITION OF THE CEILING     X  
9.1.A WHAT IS THE CONDITION OF THE WALLS      X 
9.2.A WHAT IS THE CONDITION OF THE FLOOR      X 
9.3.A WHAT IS THE CONDITION OF THE WINDOWS     X  
9.4.A WHAT IS THE CONDITION OF THE DOORS  X     
9.5.A WHAT IS THE CONDITION OF THE OUTLETS AND WALL SWITCHES     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
CEILING MATERIAL:
SHEETROCK
 
WALL MATERIAL:
WALLPAPER
WOOD WAINSCOATING
 
FLOOR COVERING:
HARDWOOD T&G
 
Comments:
9.1.A Wallpaper and Sheetrock on wall is cracked above door opening, indicating a possible settlement problem. Recommend evaluation by a licensed contractor.

9.1.A Picture 1
9.2.A There is a 1 1/2" fall in a 4' span at doorway to kitchen indicating a probable settling problem.  Recommend evaluation by a licensed contractor for needed repairs.

9.2.A Picture 1
9.4.A There are no doors in the Dining Area(s)

Breakfast Room

 NINPN/AYNSatPRMI
9.0.B WHAT IS THE CONDITION OF THE CEILING     X  
9.1.B WHAT IS THE CONDITION OF THE WALLS     X  
9.2.B WHAT IS THE CONDITION OF THE FLOOR     X  
9.3.B WHAT IS THE CONDITION OF THE WINDOWS     X  
9.4.B WHAT IS THE CONDITION OF THE DOORS     X  
9.5.B WHAT IS THE CONDITION OF THE OUTLETS AND WALL SWITCHES     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
CEILING MATERIAL:
SHEETROCK
 
WALL MATERIAL:
SHEETROCK
 
FLOOR COVERING:
HARDWOOD T&G
 

Formal Living Room

 NINPN/AYNSatPRMI
10.0.A WHAT IS THE CONDITION OF THE CEILING     X  
10.1.A WHAT IS THE CONDITION OF THE WALLS     X  
10.2.A WHAT IS THE CONDITION OF THE FLOORS     X  
10.3.A WHAT IS THE CONDITION OF THE WINDOWS     X  
10.4.A WHAT IS THE CONDITION OF THE DOORS  X     
10.5.A WHAT IS THE CONDITION OF THE OUTLETS AND WALL SWITCHES     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
CEILING MATERIAL:
WALLPAPER
 
WALL MATERIAL:
WALLPAPER
 
FLOOR COVERING:
HARDWOOD T&G
 
Comments:
10.4.A There are no doors.

Upper Family Room

 NINPN/AYNSatPRMI
10.0.B WHAT IS THE CONDITION OF THE CEILING     X  
10.1.B WHAT IS THE CONDITION OF THE WALLS     X  
10.2.B WHAT IS THE CONDITION OF THE FLOORS     X  
10.3.B WHAT IS THE CONDITION OF THE WINDOWS     X  
10.4.B WHAT IS THE CONDITION OF THE DOORS     X  
10.5.B WHAT IS THE CONDITION OF THE OUTLETS AND WALL SWITCHES     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
CEILING MATERIAL:
SHEETROCK
 
WALL MATERIAL:
SHEETROCK
 
FLOOR COVERING:
CARPET
 

Sunroom

 NINPN/AYNSatPRMI
10.0.C WHAT IS THE CONDITION OF THE CEILING     X  
10.1.C WHAT IS THE CONDITION OF THE WALLS     X  
10.2.C WHAT IS THE CONDITION OF THE FLOORS     X  
10.3.C WHAT IS THE CONDITION OF THE WINDOWS     X  
10.4.C WHAT IS THE CONDITION OF THE DOORS  X     
10.5.C WHAT IS THE CONDITION OF THE OUTLETS AND WALL SWITCHES     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
CEILING MATERIAL:
SHEETROCK
 
WALL MATERIAL:
SHEETROCK
 
FLOOR COVERING:
TILE
 
Comments:
10.4.C There are no doors.

Lower Family Room

 NINPN/AYNSatPRMI
10.0.D WHAT IS THE CONDITION OF THE CEILING     X  
10.1.D WHAT IS THE CONDITION OF THE WALLS     X  
10.2.D WHAT IS THE CONDITION OF THE FLOORS     X  
10.3.D WHAT IS THE CONDITION OF THE WINDOWS     X  
10.4.D WHAT IS THE CONDITION OF THE DOORS     X  
10.5.D WHAT IS THE CONDITION OF THE OUTLETS AND WALL SWITCHES     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
CEILING MATERIAL:
SHEETROCK
 
WALL MATERIAL:
SHEETROCK
 
FLOOR COVERING:
CARPET
 

OFFICE

 NINPN/AYNSatPRMI
10.0.E WHAT IS THE CONDITION OF THE CEILING     X  
10.1.E WHAT IS THE CONDITION OF THE WALLS     X  
10.2.E WHAT IS THE CONDITION OF THE FLOORS     X  
10.3.E WHAT IS THE CONDITION OF THE WINDOWS  X     
10.4.E WHAT IS THE CONDITION OF THE DOORS     X  
10.5.E WHAT IS THE CONDITION OF THE OUTLETS AND WALL SWITCHES       X
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
CEILING MATERIAL:
SHEETROCK
 
WALL MATERIAL:
SHEETROCK
 
FLOOR COVERING:
CARPET
 
Comments:
10.3.E There are no windows.
10.5.E "Three-prong" outlet is not grounded. Needs correcting.

10.5.E Picture 1

FIREPLACES

 NINPN/AYNSatPRMI
11.0 IS CLEARANCE TO COMBUSTIBLES ADEQUATE   X    
11.1 IS THERE A DAMPER  X     
11.2 WHAT IS THE CONDITION OF HEARTH, MANTLE AND WALL     X  
11.3 WHAT IS THE CONDITION OF THE FIRE-BRICK WALLS     X  
11.4 WAS LINER INSPECTED OR FULLY VISIBLE FROM END TO END  X     
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
TYPES OF FIREPLACES:
NON-VENTED GAS LOGS
 
OPERABLE FIREPLACES:
ONE
 
Comments:
11.1 The fireplace is non-vented and has no damper or flue.
11.4 The fireplace is non-vented and has no damper or flue.

MASTER BEDROOM

 NINPN/AYNSatPRMI
12.0.A WHAT IS THE CONDITION OF THE CEILING     X  
12.1.A WHAT IS THE CONDITION OF THE WALLS     X  
12.2.A WHAT IS THE CONDITION OF THE FLOORS     X  
12.3.A WHAT IS THE CONDITION OF THE WINDOWS     X  
12.4.A WHAT IS THE CONDITION OF THE DOORS     X  
12.5.A WHAT IS THE CONDITION OF THE OUTLETS AND WALL SWITCHES     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
CEILING MATERIAL:
SHEETROCK
 
WALL MATERIAL:
SHEETROCK
 
FLOOR COVERING:
CARPET
 

LARGE LOWER LEVEL BEDROOM

 NINPN/AYNSatPRMI
12.0.B WHAT IS THE CONDITION OF THE CEILING     X  
12.1.B WHAT IS THE CONDITION OF THE WALLS     X  
12.2.B WHAT IS THE CONDITION OF THE FLOORS     X  
12.3.B WHAT IS THE CONDITION OF THE WINDOWS     X  
12.4.B WHAT IS THE CONDITION OF THE DOORS       X
12.5.B WHAT IS THE CONDITION OF THE OUTLETS AND WALL SWITCHES     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
CEILING MATERIAL:
SHEETROCK
 
WALL MATERIAL:
SHEETROCK
 
FLOOR COVERING:
CARPET
 
Comments:
12.4.B Entry door and Door to bathroom rubs floor when opened. Doors need to be trimmed at bottom by a skilled craftsman.

12.4.B Picture 1

12.4.B Picture 2

BACK LOWER LEVEL BEDROOM

 NINPN/AYNSatPRMI
12.0.C WHAT IS THE CONDITION OF THE CEILING     X  
12.1.C WHAT IS THE CONDITION OF THE WALLS     X  
12.2.C WHAT IS THE CONDITION OF THE FLOORS     X  
12.3.C WHAT IS THE CONDITION OF THE WINDOWS     X  
12.4.C WHAT IS THE CONDITION OF THE DOORS       X
12.5.C WHAT IS THE CONDITION OF THE OUTLETS AND WALL SWITCHES     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
CEILING MATERIAL:
SHEETROCK
 
WALL MATERIAL:
SHEETROCK
 
FLOOR COVERING:
CARPET
 
Comments:
12.4.C Entry door rubs at top when closing and needs adjusting.

12.4.C Picture 1

FRONT LOWER LEVEL BEDROOM

 NINPN/AYNSatPRMI
12.0.D WHAT IS THE CONDITION OF THE CEILING     X  
12.1.D WHAT IS THE CONDITION OF THE WALLS     X  
12.2.D WHAT IS THE CONDITION OF THE FLOORS     X  
12.3.D WHAT IS THE CONDITION OF THE WINDOWS     X  
12.4.D WHAT IS THE CONDITION OF THE DOORS     X  
12.5.D WHAT IS THE CONDITION OF THE OUTLETS AND WALL SWITCHES     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
CEILING MATERIAL:
SHEETROCK
 
WALL MATERIAL:
SHEETROCK
 
FLOOR COVERING:
CARPET
 

BATHROOM(S)

 NINPN/AYNSatPRMI
13.0 WHAT IS THE CONDITION OF THE CEILING     X  
13.1 WHAT IS THE CONDITION OF THE WALLS     X  
13.2 WHAT IS THE CONDITION OF THE FLOORS     X  
13.3 WHAT IS THE CONDITION OF THE WINDOWS     X  
13.4 WHAT IS THE CONDITION OF THE DOORS     X  
13.5 ARE BATHROOM OUTLETS GFCI PROTECTED   X  X 
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
CEILING MATERIAL:
SHEETROCK
 
WALL MATERIAL:
SHEETROCK
 
FLOOR COVERING:
TILE
 
Comments:
13.5 GFCI outlet(s) is defective (won't trip with test-plug) at Master bathroom. Recommend evaluation/repair by a licensed Electrician .

BATHROOM COMMPONENTS

 NINPN/AYNSatPRMI
14.0 WHAT IS CONDITION OF SINK BASE AND CABINETRY     X  
14.1 WHAT IS CONDITION OF PLUMBING FIXTURES     X  
14.2 ARE CUT-OFF VALVES UNDER SINK AND TOILET   X    
14.3 DOES SINK PLUMBING OPERATE PROPERLY   X    
14.4 DO THE SINK FAUCET(S)AND STOP VALVE OPERATE PROPERLY   X    
14.5 DOES THE TOILET OPERATE PROPERLY   X    
14.6 DO FIXTURES DRAIN PROPERLY   X    
14.7 DO THE SHOWER AND TUB FAUCETS AND STOP VALVES OPERATE PROPERLY   X    
14.8 WHAT IS THE CONDITION OF CAULKING ALONG PERIMETER OF TUB/SHOWER AND FLOOR     X  
14.9 DOES THE EXHAUST FAN OPERATE PROPERLY   X    
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
EXHAUST FAN TYPE:
FAN WITH LIGHT
 

Foyer

 NINPN/AYNSatPRMI
15.0 WHAT IS THE CONDITION OF THE CEILING     X  
15.1 WHAT IS THE CONDITION OF THE WALLS     X  
15.2 WHAT IS THE CONDITION OF THE FLOORS     X  
15.3 WHAT IS THE CONDITION OF THE WINDOWS  X     
15.4 WHAT IS THE CONDITION OF THE DOORS  X     
15.5 WHAT IS THE CONDITION OF THE OUTLETS AND WALL SWITCHES     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
CEILING MATERIALS:
SHEETROCK
 
WALL MATERIAL:
SHEETROCK
 
FLOOR COVERING:
HARDWOOD T&G
 
Comments:
15.3 There are no windows.
15.4 There are no doors.

INTERIOR STAIRS

 NINPN/AYNSatPRMI
16.0 WHAT IS THE OVERALL CONDITION OF STEPS, STAIRWAYS, BALCONIES AND RAILINGS     X  
16.1 ARE STEPS UNIFORM IN HEIGHT   X    
16.2 ARE GUARDRAILS SECURE   X    
16.3 ARE PICKETS SPACED 4 INCHES APART OR LESS (Safety issue for children)   X    
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
 

ELECTRICAL

 NINPN/AYNSatPRMI
17.0 WHAT IS THE CONDITION OF THE SERVICE ENTRANCE CONDUCTORS     X  
17.1 WHAT IS THE CONDITION OF THE SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS     X  
17.2 IS THERE A BOND WIRE FROM ELECTRIC PANEL TO METAL PLUMBING   X    
17.3 DOES THE METERBASE HAVE A GROUND WIRE AND ROD   X    
17.4 WHAT IS THE CONDITION OF WIRING, CIRCUITS, OR FUSES INSIDE MAIN PANEL (Branch circuit conductors, Over-current devices, and compatibility of their amperage and voltage)     X  
17.5 ARE THE CIRCUITS OR FUSES LABELED CLEARLY   X    
17.6 ARE THE CIRCUIT BREAKERS THE SAME BRAND NAME AS PANEL   X    
17.7 ARE SMOKE DETECTORS PRESENT IN HOME   X    
17.8 WHAT IS THE OVERALL CONDITION OF THE CONNECTED DEVICES AND FIXTURES (Observed from operating a representative number of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)     X  
17.9 WHAT IS THE CONDITION OF THE POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES AND ALL RECEPTACLES IN GARAGE/CARPORT AND EXTERIOR WALLS OF INSPECTED STRUCTURE     X  
17.10 ARE INSTALLED GFCI (GROUND FAULT CIRCUIT INTERRUPTERS) OPERATIONAL    X   
17.11 ARE ARC FAULT INTERRUPT BREAKERS INSTALLED ON CIRCUITS WITH BEDROOM OUTLETS  X     
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
ELECTRIC SERVICE:
UNDERGROUND
 
ELECTRICAL CONDUCTORS:
BELOW GROUND
 
PANEL CAPACITY:
(2) 200 AMP SERVICE PANEL
 
PANEL TYPE:
CIRCUITS
 
ELEC. PANEL MANUFACTURER:
SIEMENS
 
WIRING METHODS:
ROMEX
 
BRANCH WIRE 15 and 20 AMP:
COPPER
 
NUMBER 15 AMPS:
NONE
 
NUMBER 20 AMPS:
(37)
 
Comments:
17.10 See comments under garage and bathrooms.
17.11 Home was built prior to to requirement for ARC Fault interrupt breakers on bedroom circuits.

PLUMBING

 NINPN/AYNSatPRMI
18.0 WHAT IS THE CONDITION OF THE INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES     X  
18.1 WHAT IS THE CONDITION OF THE INTERIOR DRAIN, WASTE AND VENT SYSTEMS     X  
18.2 WERE ANY LEAKS OR CROSS-CONNECTIONS ON SUPPLY OR WASTE LINES OBSERVED    X   
18.3 WHAT IS THE CONDITION OF THE FUNCTIONAL FLOW (water pressure and volume)     X  
18.4 WAS THE MAIN WATER VALVE LOCATED   X    
18.5 WHAT IS THE CONDITION OF EXTERIOR FAUCETS       X
18.6 WHAT IS THE CONDITION OF THE WATER HEATER(S)     X  
18.7 IS WATER HEATER WIRING SECURED PROPERLY   X    
18.8 IS THE T&P VALVE PIPED WITHIN 6 INCHES OF FLOOR   X    
18.9 WHAT IS THE CONDITION OF THE VENT PIPE (from furnace/water heater to chimney)  X     
18.10 WAS CHIMNEY LINER INSPECTED (for gas water heater only)  X     
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
PLUMBING SUPPLY:
NOT VISIBLE
 
DISTRIBUTION:
COPPER
 
PLUMBING WASTE:
PVC
 
WATER SOURCE:
PUBLIC
 
WATER HEATER POWER SOURCE:
ELECTRIC
 
CAPACITY:
80 GAL
 
MANUFACTURER:
GE
 
SEWAGE DISPOSAL SYSTEM:
PUBLIC SEWER
 
Comments:
18.4 The main shut-off is the blue knob underneath in crawlspace.

18.4 Picture 1
18.5 Exterior faucet(s) is not frost proof and is not sealed where it penetrates wall at exterior.

Water supply lines for deck faucets should have insulation to prevent freezing.



18.5 Picture 1

18.5 Picture 2
18.9 Water heater is electric and does not require a vent pipe or chimney.
18.10 Water heater is electric and does not require a vent pipe or chimney.

HEATING/COOLING

 NINPN/AYNSatPRMI
19.0 WHAT IS THE CONDITION OF THE THERMOSTAT(S)     X  
19.1 IS THERE A HUMIDIFIER    X   
19.2 WHAT IS THE CONDITION OF THE HEATING EQUIPMENT     X  
19.3 WHAT IS THE CONDITION OF THE COMBUSTION AIR SUPPLY  X     
19.4 WHAT IS THE CONDITION OF THE COOLING AND AIR HANDLER EQUIPMENTX       
19.5 WHAT IS THE CONDITION OF THE CONDENSATION LINE AND/OR PUMP       X
19.6 WHAT IS THE CONDITION OF THE NORMAL OPERATING CONTROLS     X  
19.7 WHAT IS THE CONDITION OF THE CHIMNEYS, FLUES AND VENTS (FOR FURNACE)  X     
19.8 WHAT IS THE CONDITION OF THE DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)       X
19.9 IS THERE AN INSTALLED HEATING/COOLING SOURCE IN EACH ROOM   X    
19.10 WHAT IS THE AIR TEMPERATURE AT REGISTERS       X
19.11 WHAT IS THE AMBIENT AIR TEMPERATURE OF COOLING SYSTEMX       
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
EVALUATION MODE:
HEAT PUMP IN HEATING MODE
 
NUMBER OF HEATING/COOLING SYSTEMS (excluding wood):
TWO
 
FUEL SOURCE:
ELECTRIC
 
HEAT TYPE:
HEAT PUMP (FORCED AIR)
 
HEAT SYSTEM BRAND:
AMERICAN STANDARD
 
FILTER SIZE:
(Two filters)
20x30
 
FILTER TYPE:
DISPOSABLE
 
DUCTWORK:
INSULATED
 
Comments:
19.3 Unit is electric heat pump.
19.4 Outside temperature was below 65 degrees, function of air conditioning system could not be tested without causing possible damage to unit. AC was turned on only long enough to verify that it was functioning.
19.5 Condensation drain line needs an extension to carry water away from home.

19.5 Picture 1

19.5 Picture 2
19.7 Unit is electric heat pump.
19.8 Supply ducts are sagging in crawlspace. Recommend ducts be strapped up to prevent moisture build up when air conditioning system is in use.

19.8 Picture 1

19.8 Picture 2
19.10 The temperature at register is 92 degrees on upstairs unit and on the downstairs unit read 107 degrees, indicating that the upper level unit is not functioning properly. Recommend evaluation/repair by a licensed HVAC contractor .
19.11 Air conditioning system not tested because outside temperature was below 65 degrees and operation of unit could cause damage to unit.

ATTIC AND ROOF STRUCTURE

 NINPN/AYNSatPRMI
20.0 IS THERE AN ATTIC ACCESS   X    
20.1 IS THERE INSULATION IN ATTIC   X    
20.2 DO RAFTERS APPEAR TO BE IN GOOD CONDITION   X    
20.3 DOES ROOF APPEAR TO BE ADEQUATELY BRACED   X    
20.4 ARE THERE ANY VISIBLE SIGNS OF LEAKS OR ABNORMAL CONDENSATION    X   
20.5 IS THERE CROSS-VENTILATION   X    
20.6 ARE THERE ANY VISIBLE SIGNS OF DETERIORATION    X   
20.7 ARE BATHROOM AND KITCHEN EXHAUST FANS VENTED TO EXTERIOR    X  X
20.8 IS THERE ANY DEBRIS IN ATTIC   X    
20.9 IS THERE ANY UNSAFE ELECTRICAL WIRING IN ATTIC    X   
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
ATTIC INFO:
PULL DOWN STAIRS
 
INSULATION:
BLOWN
 
R- VALUE:
R-30 OR BETTER
 
ROOF STRUCTURE:
2 X 6 RAFTERS
STICK-BUILT
 
ROOF SHEATHING:
OSB
 
CEILING STRUCTURE:
2X8
 
Comments:
20.0 Pull down stairs are located in garage.
20.7 Recommend bathroom exhaust fan(s) be vented to exterior to prevent possible mold buildup in insulation.

20.7 Picture 1
20.8 Personal items still remain in Attic.

CRAWLSPACE FOUNDATION

 NINPN/AYNSatPRMI
21.0 WHAT IS THE CONDITION OF THE FOUNDATION WALLS     X  
21.1 WHAT IS THE CONDITION OF THE FLOOR STRUCTURE     X  
21.2 WHAT IS THE CONDITION OF THE GIRDERS, PIERS, COLUMNS AND SUPPORTS     X  
21.3 ARE THERE ANY VISIBLE SIGNS OF DETERIORATION    X   
21.4 IS THERE A VAPOR BARRIER ON DIRT FLOOR OF CRAWLSPACE    X  X
21.5 IS CRAWLSPACE CEILING INSULATED    X   
21.6 IS THERE ANY DEBRIS IN CRAWLSPACE   X    
21.7 ARE THERE FOUNDATION VENTS OR WINDOWS   X    
21.8 ARE THERE ANY WET OR UNUSUALLY DAMP AREA    X   
21.9 IS THERE A SUMP PUMP    X   
21.10 WERE SOME AREAS OF CRAWLSPACE INACCESSIBLE    X   
21.11 IS THERE ANY UNSAFE WIRING IN CRAWLSPACE    X   
21.12 WHAT IS THE CONDITION OF PLUMBING SUPPLY AND WASTE LINES     X  
NI=Not Inspected, NP=Not Present, N/A=Not Applicable, Y=Yes, N=No, Sat=Satisfactory, PR=Poor, MI=Maintenance Issues
Styles & Materials
METHOD USED TO OBSERVE CRAWLSPACE:
CRAWLED
 
FOUNDATION:
MASONRY BLOCK
 
FLOOR STRUCTURE:
2 X 10
WOOD JOISTS
 
Comments:
21.4 Vapor barrier (plastic) is needed where missing. Recommend 6 mil thick plastic be spread over area missing.

21.4 Picture 1

21.4 Picture 2
21.6 Personal items remains in crawlspace.

Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2004 : Licensed To APHIS



General Summary


APHIS

P.O. Box 1228
Athens, AL 35612
256-216-0021

Customer
Albert Smith
Jane Smith

Property Address
123 Main St.
Your Town, AL 356XX

The following items or discoveries were rated poor indicating that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or appear to warrant further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function, efficiency, or safety of the home. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.

EXT. WINDOWS & DOORS
3.0 WHAT IS THE OUTSIDE CONDITION OF WINDOWS AND/OR SKYLIGHTS
 Poor
 
Sillplate and Brickmold deteriorated and needs replacing to prevent possible water intrusion at front of home and rear of home.

Formal Dining Room
9.1.A WHAT IS THE CONDITION OF THE WALLS
 Poor
 
Wallpaper and Sheetrock on wall is cracked above door opening, indicating a possible settlement problem. Recommend evaluation by a licensed contractor.
9.2.A WHAT IS THE CONDITION OF THE FLOOR
 Poor
 
There is a 1 1/2" fall in a 4' span at doorway to kitchen indicating a probable settling problem.  Recommend evaluation by a licensed contractor for needed repairs.

BATHROOM(S)
13.5 ARE BATHROOM OUTLETS GFCI PROTECTED
 Yes, Poor
 
GFCI outlet(s) is defective (won't trip with test-plug) at Master bathroom. Recommend evaluation/repair by a licensed Electrician .


Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2004 : Licensed To APHIS




Maintenance Summary


APHIS

P.O. Box 1228
Athens, AL 35612
256-216-0021

Customer
Albert Smith
Jane Smith

Property Address
123 Main St.
Your Town, AL 356XX

The following items or discoveries were rated maintenance issues,indicating that these items have minor deficiencies normally associated with a lack of routine maintenance and require subsequent observation and/or repair as deemed appropriate.

EXTERIOR WALLS & EAVES
2.1 WHAT IS THE CONDITION OF EXTERIOR WALL COVERINGS, FLASHING
 Maintenance Issues
 
Composite board siding at rear of home at upper deck deteriorated, and needs replacing.

EXT. WINDOWS & DOORS
3.2 WHAT IS THE CONDITION OF EXTERIOR ENTRY DOORS
 Maintenance Issues
 
Rear entry door at Sun room has deteriorated at brickmold or trim (exterior). Needs repair or replace, prep and paint.

Rear entry door at Family room rubs at sill and has deteriorated at brickmold or trim (exterior). Needs repair or replace, prep and paint.

Main entry door at Foyer does not fit opening properly (out of square) and needs strike adjustment for deadbolt and door knob to latch properly.

Rear entry door at Family room has damaged or aged weather stripping.


DECKS & PORCHES
4.1 WHAT IS THE CONDITION OF DECKS, STAIRS AND HANDRAILS OR BALCONIES
 Maintenance Issues
 
Guardrails and pickets on steps to basement at left side of home (facing front) loose and needs tighten or repair.

LANDSCAPING AND DRAINAGE
5.0 DOES LANDSCAPE FAVOR PROPER DRAINAGE
 Maintenance Issues
 
Dirt bank at left side (facing front) and right side (facing front) is eroding. Silt travel is occurring and has pushed against fence and gates causing damage to gates.  Recommend some form of ground cover or landscaping and repairing gates..
5.1 WHAT IS THE CONDITION OF WALKWAYS AND DRIVEWAY
 Maintenance Issues
 
Concrete drive at front of home shows signs of erosion and problem needs to be addressed.
5.2 WHAT IS THE CONDITION OF RETAINING WALL(S), (AS IT PERTAINS TO PROPER DRAINAGE)
 Maintenance Issues
 
Retaining wall has shifted somewhat, but it appears as old settlement. Wall appears stable at present.

GARAGE
6.5 ARE OUTLETS GFCI PROTECTED
 Maintenance Issues
 
GFCI outlet did not trip when tested. Recommend repair by a licensed electrical contractor..

OFFICE
10.5.E WHAT IS THE CONDITION OF THE OUTLETS AND WALL SWITCHES
 Maintenance Issues
 
"Three-prong" outlet is not grounded. Needs correcting.

LARGE LOWER LEVEL BEDROOM
12.4.B WHAT IS THE CONDITION OF THE DOORS
 Maintenance Issues
 
Entry door and Door to bathroom rubs floor when opened. Doors need to be trimmed at bottom by a skilled craftsman.

BACK LOWER LEVEL BEDROOM
12.4.C WHAT IS THE CONDITION OF THE DOORS
 Maintenance Issues
 
Entry door rubs at top when closing and needs adjusting.

PLUMBING
18.5 WHAT IS THE CONDITION OF EXTERIOR FAUCETS
 Maintenance Issues
 
Exterior faucet(s) is not frost proof and is not sealed where it penetrates wall at exterior.

Water supply lines for deck faucets should have insulation to prevent freezing.


HEATING/COOLING
19.5 WHAT IS THE CONDITION OF THE CONDENSATION LINE AND/OR PUMP
 Maintenance Issues
 
Condensation drain line needs an extension to carry water away from home.
19.8 WHAT IS THE CONDITION OF THE DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)
 Maintenance Issues
 
Supply ducts are sagging in crawlspace. Recommend ducts be strapped up to prevent moisture build up when air conditioning system is in use.
19.10 WHAT IS THE AIR TEMPERATURE AT REGISTERS
 Maintenance Issues
 
The temperature at register is 92 degrees on upstairs unit and on the downstairs unit read 107 degrees, indicating that the upper level unit is not functioning properly. Recommend evaluation/repair by a licensed HVAC contractor .

ATTIC AND ROOF STRUCTURE
20.7 ARE BATHROOM AND KITCHEN EXHAUST FANS VENTED TO EXTERIOR
 No, Maintenance Issues
 
Recommend bathroom exhaust fan(s) be vented to exterior to prevent possible mold buildup in insulation.

CRAWLSPACE FOUNDATION
21.4 IS THERE A VAPOR BARRIER ON DIRT FLOOR OF CRAWLSPACE
 No, Maintenance Issues
 
Vapor barrier (plastic) is needed where missing. Recommend 6 mil thick plastic be spread over area missing.


Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2004 : Licensed To APHIS



Alabama Professional Home Inspection Services (APHIS)
Athens, AL 35613-2808
Phone: (256) 216-0021
Fax: (256) 216-0021
inspection@aphisal.com